PJM Transmission Owners file tariff revisions for service to co-located and large loads under section 205
The PJM Transmission Owners file tariff revisions under section 205 on November 16, 2026, in a new docket, ER27-520-000. The filing sets rates for the new co-located and large-load services, a pro forma cost recovery agreement with a minimum revenue commitment and credit support, and a 15-year zonal allocation of upgrade costs from PJM’s Fast Energization Process.
Asks FERC to: Accept the tariff revisions without hearing, modification or condition, with the new service rates effective March 16, 2027 and the agreement and cost allocation on an indeterminate date.
Answers the order. Filed under section 205 to answer the E-7 show cause order for PJM. The owners also say it meets their compliance obligation under the E-2 co-location order and will tell the EL25-49 parties so by letter.
E-7 PJM: Show cause or propose tariff changes in 60 days (p. 7) E-7 PJM: Cost-recovery agreement (P 77, p. 28) E-7 PJM: Cost transparency (P 71, p. 51) E-2 PJM: Paper hearing sets the rates (Disposition, p. 5) E-2 PJM: One of three new co-location services (P 2, p. 3)
Key points
- The owners say the revisions answer the E-7 show cause order and comply with the E-2 co-location order.
These revisions are both responsive to and consistent with the preliminary findings made by the Commission in its June 18, 2026 Order Instituting Proceeding PDF p. 1
- Large Load customers would make a minimum contribution to transmission revenue requirements, backed by shortfall payments and financial security.
to make a minimum contribution towards transmission owners’ revenue requirements, along with a shortfall payment and crediting mechanism and financial security obligations PDF p. 2
- The committed contribution is 80% to 100% of a full firm transmission service benchmark.
which percentage shall be no less than 80% and no greater than 100% PDF p. 77
- Initial credit support equals the projected charges on the full initial load commitment over the agreement’s term.
equals the aggregate projected charges associated with 100 percent of the Initial Load Commitment over the CRA term PDF p. 18
- The cost recovery agreement runs at least ten years after the first service date.
the date that is at least ten (10) years after the first Service Date as specified in Exhibit A PDF p. 80
- Owners may keep using existing or new customer protections instead of the pro forma agreement if FERC accepts them.
as alternatives to the pro forma CRA, so long as those arrangements result in comparable protections and are accepted for filing by the Commission PDF p. 2
- Upgrade costs from Fast Energization go to the zones with large loads for 15 years, then to regional allocation.
this allocation methodology will apply to each portfolio of IRRs identified through PJM’s Fast Energization Process for 15 years PDF p. 3
- Rates for the three new transmission services largely repeat those FERC approved in the co-location order.
The rates for these services are largely identical to those proposed by the PJM Transmission Owners and approved by the Commission in the Co-Located Load Paper Hearing Order PDF p. 3
- The owners say FERC should accept their proposal whatever it decides on PJM’s companion filing.
regardless of how the Commission acts on PJM’s filing, the Commission can and should determine that the key aspects of the PJM Transmission Owners’ proposal PDF p. 4
- The owners ask FERC to set the same comment date as for PJM’s companion filing.
request that the Commission establish the same comment date for the instant filing that it establishes for PJM’s filing PDF p. 46
Topics in the text: Cost allocation · Connecting load and generation · Registry access
Source sections
Printed headings where available; page ranges otherwise. Excerpts below are selected from the text by keyword.
Opening text
opening text · Topic match: Cost allocation
EL25-49, et al. (“Co-Located Load Paper Hearing Order”).9 Additionally, the proposed tariff revisions have been designed to be consistent with PJM’s responsive section 205 filings establishing provisions for: (1) a new Fast Energization Process for generation interconnection and Large Load-related…Read this passage
I. EXECUTIVE SUMMARY
printed heading
I.Read this passage
EXECUTIVE SUMMARY
printed heading · Topic match: Cost allocation
The PJM Transmission Owners are also proposing that all IRRs be allocated to Zones containing Large Load-related transmission requests for 15 years, after which point the remaining costs will be allocated using the then-current general regional cost allocation methodology.Read this passage
II. BACKGROUND
printed heading
II.Read this passage
BACKGROUND
printed heading
BACKGROUNDRead this passage
A. PJM Transmission Owner Filing Rights
printed heading · Topic match: Cost allocation
PJM Transmission Owner Filing Rights As the Commission has noted, the PJM Transmission Owners have exclusive and unilateral rights regarding the cost allocation provisions of Schedule 12 of the Tariff.16 The PJM Transmission Owners relied on those same authorities in their February 23, 2026 paper…Read this passage
B. Procedural Background
printed heading · Topic match: Connecting load and generation
Reese November 16, 2026 Page 8 On December 18, 2025, the Commission found the Tariff to be unjust and unreasonable and established a framework under which an Eligible Customer taking transmission service on behalf of Co-Located Load must take: (1) NITS, including interim non-firm service pending…Read this passage
III. DISCUSSION
printed heading
III.Read this passage
DISCUSSION
printed heading
DISCUSSIONRead this passage
A. Pro Forma Cost Recovery Agreement and Related Tariff Provisions
printed heading · Topic match: Cost allocation
The Large Load Customer must identify and reflect in the CRA its: (i) anticipated load demand, (ii) proposed schedule for ramping up such demand, if any, and (iii) anticipated dates for each stage of service.Read this passage
B. Transmission Service Rates and Related Charges for Co-Located Load and
printed heading · Topic match: Connecting load and generation
Accordingly, the PJM Transmission Owners’ filing implements the rate treatments already found just and reasonable for FCDS and Interim NITS through compliance tariff records,108 and proposes a revised NFCDS discounted rate methodology and related tariff provisions in compliance with the…Read this passage
C. Extension of Transmission Services and Financial Penalties for Unreserved
printed heading · Topic match: Connecting load and generation
PTO-0006 at 1-2. 146 Id. at 1. 147 Co-Located Load Paper Hearing Order at P 248. 148 Id. at P 248. 149 Co-Located Load Paper Hearing Order at PP 572-573. 150 See Co-Located Load Paper Hearing Order at P 573; see also PJM Interconnection, L.L.C., Co-Located Load Order Workshop Meeting Materials,…Read this passage
D. Cost Allocation and Recovery for Interconnection Reliability Reinforcements
printed heading · Topic match: Cost allocation
In balancing the need for a cost allocation methodology that assigns costs in a manner roughly commensurate with benefits while also being efficient, practically implementable, and protecting other transmission customers, the PJM Transmission Owners’ proposed cost allocation approach is intended…Read this passage
IV. EFFECTIVE DATE AND IMPLEMENTATION
printed heading
EFFECTIVE DATE AND IMPLEMENTATION The PJM Transmission Owners understand that PJM intends to request an effective date of March 16, 2027 for the proposed revisions to Parts I, III, VI, VII, IX, XI, Attachment F-3,Read this passage
Attachment F-3A, Attachment F-4, and certain parts of Part VIII to the Tariff. For the remaining
printed heading · Topic match: Connecting load and generation
Accordingly, given the interrelated nature of the filings, the PJM Transmission Owners request an effective date of March 16, 2027 for their proposed revisions to Tariff, Part XI and Schedules 20, 21, and 22, and an effective date of 12/31/9998 for the proposed pro forma CRA (Part IX, Subpart P);…Read this passage
V. ADDITIONAL FILING INFORMATION
printed heading
V.Read this passage
A. Request for Waiver.
printed heading
To the extent necessary, the PJM Transmission Owners request waiver of the requirement to submit the cost of service data required by 18 C.F.R. § 35.13.Read this passage
B. Documents Submitted With This Filing.
printed heading
The PJM Transmission Owners submit the following materials: 1.Read this passage
C. Communications.
printed heading
Communications regarding this filing should be addressed to the following individuals, whose names should be entered on the official service list maintained by the Secretary for this proceeding: Pulin Shah Vice President, Transmission Development EXELON CORPORATION 2301 Market Street Philadelphia,…Read this passage
D. Service.
printed heading
PJM has served a copy of this filing on all PJM Members and on all state utility regulatory commissions in the PJM Region by posting this filing electronically.Read this passage
VI. CONCLUSION
printed heading
VI.Read this passage
CONCLUSION
printed heading
CONCLUSION For the reasons stated herein, the PJM Transmission Owners respectfully request that the Commission accept the Tariff revisions without hearing, modification or condition.Read this passage
Attachment A
printed heading · Topic match: Connecting load and generation
Reasonable Efforts: Page 2 “Reasonable Efforts” shall mean, with respect to any action required to be made, attempted, or taken by an Interconnection Party or by a Construction Party under Tariff, Part IV or Part VI, an Interconnection Service Agreement, or a Construction Service Agreement, such…Read this passage
Attachment K-Appendix, section 6.6(c) or the defaults below:
printed heading · Topic match: Registry access
Information shall constitute Confidential Information only if: (i) it is identified as confidential when disclosed; or (ii) its nature or the circumstances of disclosure would reasonably indicate that it is confidential. 14.2 Exclusions Confidential Information does not include information that the…Read this passage
Attachment H-11 and
printed heading
Attachment H-11 andRead this passage
Attachment H-34
printed heading
Attachment H-34 Rate Pursuant to Attachment H-11 and Attachment H-34 Rate Pursuant to Attachment H-11 and Attachment H-34 Rate Pursuant toRead this passage
Attachment H-11 and
printed heading
Attachment H-11 andRead this passage
Attachment H-34
printed heading
Attachment H-34 Rockland Zone 53.766 4.481 1.0340 0.2068 0.1477 ComEd Zone4/ 5/ AEP East Zone6/ Rate Pursuant toRead this passage
Attachment H-14 and
printed heading
Attachment H-14 andRead this passage
Attachment H-20
printed heading
Attachment H-20 Rate Pursuant toRead this passage
Attachment H-14 and
printed heading
Attachment H-14 andRead this passage
Attachment H-20
printed heading
Attachment H-20 Rate Pursuant to Attachment H-14 and Attachment H-20 Rate Pursuant to Attachment H-14 and Attachment H-20 Rate Pursuant toRead this passage
Attachment H-14 and
printed heading
Attachment H-14 andRead this passage
Attachment H-20
printed heading
Attachment H-20 Dayton Zone Rate Pursuant toRead this passage
Attachment H-15
printed heading
Attachment H-15 Rate Pursuant toRead this passage
Attachment H-15
printed heading
Attachment H-15 Rate Pursuant to Attachment H-15 Rate Pursuant to Attachment H-15 Rate Pursuant toRead this passage
Attachment H-15
printed heading
Attachment H-15 Duquesne Zone 14.17 1.18 0.27 0.0540 0.0386 Dominion Zone7/ ATSI Zone Rate Pursuant toRead this passage
Attachment H-21
printed heading
Attachment H-21 Rate Pursuant toRead this passage
Attachment H-21
printed heading
Attachment H-21 Rate Pursuant toRead this passage
Attachment H-21
printed heading
Attachment H-21 Rate Pursuant toRead this passage
Attachment H-21
printed heading
Attachment H-21 Rate Pursuant toRead this passage
Attachment H-21
printed heading
Attachment H-21 DEOK Zone Rate Pursuant toRead this passage
Attachment H-22
printed heading
Attachment H-22 Rate Pursuant toRead this passage
Attachment H-22
printed heading
Attachment H-22 Rate Pursuant toRead this passage
Attachment H-22
printed heading
Attachment H-22 Rate Pursuant toRead this passage
Attachment H-22
printed heading
Attachment H-22 Rate Pursuant toRead this passage
Attachment H-22
printed heading
Attachment H-22 EKPC Zone Rate Pursuant toRead this passage
Attachment H-24
printed heading
Attachment H-24 Rate Pursuant toRead this passage
Attachment H-24
printed heading
Attachment H-24 Rate Pursuant toRead this passage
Attachment H-24
printed heading
Attachment H-24 Rate Pursuant toRead this passage
Attachment H-24
printed heading
Attachment H-24 Rate Pursuant toRead this passage
Attachment H-24
printed heading · Topic match: Connecting load and generation
Transmission Enhancement Charges allocated to a Merchant Transmission Facility for which collection is deferred in accordance with this section (b)(x)(B)(1) shall be recorded in appropriate Transmission Provider accounts for deferred charges and collected in accordance with section (b)(x)(B)(3)…Read this passage
Attachment B
printed heading · Topic match: Connecting load and generation
Reasonable Efforts: Page 2 “Reasonable Efforts” shall mean, with respect to any action required to be made, attempted, or taken by an Interconnection Party or by a Construction Party under Tariff, Part IV or Part VI, an Interconnection Service Agreement, or a Construction Service Agreement, such…Read this passage
Attachment K-Appendix, section 6.6(c) or the defaults below:
printed heading · Topic match: Registry access
Information shall constitute Confidential Information only if: (i) it is identified as confidential when disclosed; or (ii) its nature or the circumstances of disclosure would reasonably indicate that it is confidential. 14.2 Exclusions Confidential Information does not include information that the…Read this passage
Attachment H-11 and
printed heading
Attachment H-11 andRead this passage
Attachment H-34
printed heading
Attachment H-34 Rate Pursuant to Attachment H-11 and Attachment H-34 Rate Pursuant to Attachment H-11 and Attachment H-34 Rate Pursuant toRead this passage
Attachment H-11 and
printed heading
Attachment H-11 andRead this passage
Attachment H-34
printed heading
Attachment H-34 Rockland Zone 53.766 4.481 1.0340 0.2068 0.1477 ComEd Zone4/ 5/ AEP East Zone6/ Rate Pursuant toRead this passage
Attachment H-14 and
printed heading
Attachment H-14 andRead this passage
Attachment H-20
printed heading
Attachment H-20 Rate Pursuant toRead this passage
Attachment H-14 and
printed heading
Attachment H-14 andRead this passage
Attachment H-20
printed heading
Attachment H-20 Rate Pursuant to Attachment H-14 and Attachment H-20 Rate Pursuant to Attachment H-14 and Attachment H-20 Rate Pursuant toRead this passage
Attachment H-14 and
printed heading
Attachment H-14 andRead this passage
Attachment H-20
printed heading
Attachment H-20 Dayton Zone Rate Pursuant toRead this passage
Attachment H-15
printed heading
Attachment H-15 Rate Pursuant toRead this passage
Attachment H-15
printed heading
Attachment H-15 Rate Pursuant to Attachment H-15 Rate Pursuant to Attachment H-15 Rate Pursuant toRead this passage
Attachment H-15
printed heading
Attachment H-15 Duquesne Zone 14.17 1.18 0.27 0.0540 0.0386 Dominion Zone7/ ATSI Zone Rate Pursuant toRead this passage
Attachment H-21
printed heading
Attachment H-21 Rate Pursuant toRead this passage
Attachment H-21
printed heading
Attachment H-21 Rate Pursuant toRead this passage
Attachment H-21
printed heading
Attachment H-21 Rate Pursuant toRead this passage
Attachment H-21
printed heading
Attachment H-21 Rate Pursuant toRead this passage
Attachment H-21
printed heading
Attachment H-21 DEOK Zone Rate Pursuant toRead this passage
Attachment H-22
printed heading
Attachment H-22 Rate Pursuant toRead this passage
Attachment H-22
printed heading
Attachment H-22 Rate Pursuant toRead this passage
Attachment H-22
printed heading
Attachment H-22 Rate Pursuant toRead this passage
Attachment H-22
printed heading
Attachment H-22 Rate Pursuant toRead this passage
Attachment H-22
printed heading
Attachment H-22 EKPC Zone Rate Pursuant toRead this passage
Attachment H-24
printed heading
Attachment H-24 Rate Pursuant toRead this passage
Attachment H-24
printed heading
Attachment H-24 Rate Pursuant toRead this passage
Attachment H-24
printed heading
Attachment H-24 Rate Pursuant toRead this passage
Attachment H-24
printed heading
Attachment H-24 Rate Pursuant toRead this passage
Attachment H-24
printed heading · Topic match: Connecting load and generation
Transmission Enhancement Charges allocated to a Merchant Transmission Facility for which collection is deferred in accordance with this section (b)(x)(B)(1) shall be recorded in appropriate Transmission Provider accounts for deferred charges and collected in accordance with section (b)(x)(B)(3)…Read this passage
I. INTRODUCTION
printed heading
I.Read this passage
INTRODUCTION
printed heading · Topic match: Cost allocation
In my current role, I advise regulators, utilities, grid operators, and project 1 developers on complex regulatory and market matters, with a particular focus on 2 transmission planning, cost allocation and cost recovery, and large load tariffs.Read this passage
II. BACKGROUND
printed heading
II.Read this passage
BACKGROUND
printed heading · Topic match: Cost allocation
The Large Load must execute the CRA and post credit support before it can 4 proceed through PJM’s Fast Energization Process.Read this passage
III. PURPOSE OF TESTIMONY
printed heading · Topic match: Connecting load and generation
What is the purpose of your testimony? 8 A. [Blazunas and Hammer] The purpose of this testimony is to describe and support certain 9 PJM Transmission Owners’ Tariff revisions submitted in response to the Show Cause 10 Order and Co-Located Load Paper Hearing Order.Read this passage
IV. EXTENSION OF APPROVED RATE DESIGN ELEMENTS TO LARGE LOAD-
printed heading · Topic match: Connecting load and generation
PTO-0001 Page 8 of 43 basis.”10 In its filing in response to the Show Cause Order, PJM is proposing to extend the 1 new transmission services (FCDS, NFCDS, and Interim NITS) to Eligible Customers 2 taking service on behalf of Large Load customers, in addition to Co-Located Load. 3 Consequently, the…Read this passage
V. PROPOSED RATE FOR NON-FIRM CONTRACT DEMAND TRANSMISSION
printed heading · Topic match: Connecting load and generation
In short, the discounted 17 NFCDS rate for a given Zone is calculated as the zonal FCDS rate multiplied by the 18 transmission system load factor for the Zone.16 The transmission system load factor is 19 13 Co-Located Load Paper Hearing Order at PP 402, 404, 412. 14 Id. at P 412. 15 Id. 16 Proposed…Read this passage
VI. ALLOCATION AND RECOVERY OF COSTS ASSOCIATED WITH UPGRADES
printed heading
ALLOCATION AND RECOVERY OF COSTS ASSOCIATED WITH UPGRADES 1 IDENTIFIED IN PJM’S FAST ENERGIZATION PROCESS 2Read this passage
A. Summary of Cost Allocation and Recovery
printed heading · Topic match: Cost allocation
Why are the PJM Transmission Owners proposing a new cost allocation methodology 4 as part of the response to the Commission’s Show Cause Order? 5 A. [Hammer] The Transmission Owners are proposing a new cost allocation framework 6 because PJM’s proposed Fast Energization Process will study Large…Read this passage
B. Proportional Impact Methodology
printed heading · Topic match: Cost allocation
Unlike an allocation based on project size or requested 6 MWs of service, the proportional impact methodology measures the extent to which the 7 generation interconnection and Large Load transmission service requests impact the 8 underlying reliability needs and the resulting portfolio of…Read this passage
C. Generator Reliability Reinforcement Fee
printed heading
This 15- 17 32 For purposes of calculating such weighted average, each applicable Transmission Owner’s Weighted Average Cost of Capital shall be weighted based on the ratio of the final estimated costs of the Interconnection Reliability Reinforcements that it has been designated to construct and…Read this passage
D. Interconnection Reliability Reinforcement Charge and Cost Allocation
printed heading · Topic match: Cost allocation
After 15 years, the remaining costs of Interconnection 8 Reliability Reinforcements shall be allocated and recovered pursuant to the existing 9 regional cost allocation methodology set forth in Schedule 12.Read this passage
E. Ratepayer Protection Mechanisms
printed heading · Topic match: Cost allocation
Does the PJM Transmission Owners’ proposal address potential cost shifts among 7 retail customers within the same utility? 8 A. [Hammer] Consistent with the Commission’s findings in the Show Cause Order, the PJM 9 Transmission Owners’ proposal focuses on cost allocation and potential cost shifts at…Read this passage
VIII. COST RECOVERY AGREEMENT
printed heading · Topic match: Cost allocation
If actual revenues fall below the committed amount, the Large Load 1 Customer must pay the difference as a Shortfall Amount.Read this passage